About the Fire Rated Batt Products
Specifically designed for sealing around service penetrations in walls and floors, a single fire rated board (50mm or 60mm thick) can provide high levels of fire integrity and insulation.
Tested in Block Wall, Concrete, Masonry, Plasterboard Partition and tested in Concrete Floors. Offering up to 4 hours fire resistance in accordance with BS476: Part 20: 1987 and EN 1366-3 : 2009. Up to Rw 60dB sound reduction please refer to the technical department.
The Fire Rated Batt consist of a stone fibre core coated on both sides with Coat - Spray Grade which transforms during a fire to prevent the passage of fire and smoke and the transfer of heat. Fire Rated Batt cut edges or joints should be coated with Fire Coat (Spray Grade) or Intu Mastic.
*For specific details please refer to the test certification.
For more information please download the Product Data Sheet under the Fire Test Reports
Please note: Each item is sold separately just select your item(s) and click add to cart.
Product Size Availability
Fire Rated Batt Width: 600mm x Length: 1200mm x Thickness: 50mm & Density 140kgm³ : Colour: White
Pack: (5x) 5 Fire Rated Batts
To Order Fire Coat: 5kg Tub Click here
For more sizes click here
Installation
We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on Tel: +(0)1329 841416 or email sales@intumescent.com.
Maintenance
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 Code of Practice for the Installation and Inspection of Fire Stopping.
Competency
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
Additional Notes:
Please refer to the ETA/UKCA/UL-EU sheet for fields of application for this product. For further information on installation requirements please refer to the manufacturer of the services and the wall/floor specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall/floor specification on Tel: +(0)1329 841416 or email sales@intumescent.com.
Fire Test Reports
Download the following Fire Rated Batt Product Data Sheet (PDS), Safety Data Sheet (SDS), Technical Data Sheet (TDS), European Technical Assessment Sheet (ETA), Declaration of Performance (DoP), Certificate of Constancy of Performance (CoC), UK Technical Assessment Sheet (UKTA) & UL Documentation (UL).
Fire Rated Batt Product Data Sheet
Fire Rated Batt Safety Data Sheet
Fire Rated Batt DoP Sheet
Fire Rated Batt CoC Sheet
Fire Rated Batt TDS Sheet
Fire Rated Batt ETA Sheet
Fire Rated Batt DoP UKCA Sheet
Fire Rated Batt CoC UKCA Sheet
Fire Rated Batt UKCA UKTA
Fire Rated Batt UL Documentation
We only sell and deliver goods in the Mainland UK and NI - unless you have made a prior arrangement with us. For delivery to the following postcodes starting with: IM, HS, ZE, JE, GY, KW, FK, PH33 or AB please contact us on 01329 841 416 or sales@intumescent.com for all enquiries.
Delivery charges are flat rate whatever quantity of goods you buy.
Current delivery charges (excluding VAT) are:
- £12.50 for Express Delivery (Typically 1-2 days)**
- £25.00 for AM Delivery**
- £34.75 for N. Ireland 3-5 Working Days (Monday to Friday)
** "Express & AM Delivery" applies to the normal work days, Monday to Friday, and assumes in stock orders are placed before 14:00 on a week day. For Scottish and highlands locations deliveries can take up to 3 days. For URGENT delivery enquiries please contact us.
Track your delivery
All products bought from us are tracked and you can check the progress of your delivery by contacting one of our friendly team members on
01329 841 416 or
sales@intumescent.comYou are required to sign for your order and we cannot leave items without a signature unless by prior arrangement. (Please note we cannot accept any liability for any shortage and/or damage if goods are left at your request).
Got some comments about our products or your recent purchase please send us an email and we will add it to this website:
sales@intumescent.com